Résumé
This document covers the monitoring of air cleanliness by particles in terms of concentration of airborne nanoscale particles.
For monitoring purposes, only populations of particles with a lower size limit of 0.1 microns (100 nm) or less ? "nanoscale" ? are considered.
The monitoring given in this document is for use mainly in "operational" states.
NOTE 1 For the purposes of this document, reference is made to "nanoscale particles", which means all nano-objects having one (nanoplate), two (nanofibre) or three (nanoparticle) dimensions in the nanoscale.
NOTE 2 As a consequence, the specifications for monitoring air cleanliness by nanoscale particle concentration of the cleanroom in operational state also considers process specifics, e.g., used equipment, personnel behaviour, etc.
NOTE 3 Health and safety considerations are excluded from this document.
Prévisualiser
Informations générales
-
État actuel: PubliéeDate de publication: 2018-08Stade: Clôture de l'examen [90.60]
-
Edition: 1
-
Comité technique :ISO/TC 209ICS :13.040.35
- RSS mises à jour
Cycle de vie
-
Actuellement
PubliéeISO 14644-12:2018
Les normes ISO sont réexaminées tous les cinq ans
Stade: 90.60 (En cours d'examen)
Vous avez une question?
Consulter notre FAQ
Horaires d’ouverture:
De lundi à vendredi - 09:00-12:00, 14:00-17:00 (UTC+1)